{"id":280,"date":"2026-09-04T03:12:32","date_gmt":"2026-09-04T03:12:32","guid":{"rendered":"https:\/\/blogs.lcsccable.com\/blog\/?p=280"},"modified":"2026-09-08T05:48:17","modified_gmt":"2026-09-08T05:48:17","slug":"d-sub-connector-guide-db9-db25-pinouts-and-housings","status":"publish","type":"post","link":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/","title":{"rendered":"D-Sub Connector Guide: DB9, DB25 Pinouts and Housings"},"content":{"rendered":"<h2><b><span data-font-family=\"default\">Key Takeaways<\/span><\/b><\/h2>\n<ul>\n<li><b><span data-font-family=\"default\">Standardized Signals:<\/span><\/b> <b><span data-font-family=\"default\">DB9<\/span><\/b><span data-font-family=\"default\"> connectors primarily support serial communications like RS-232, while <\/span><b><span data-font-family=\"default\">DB25<\/span><\/b><span data-font-family=\"default\"> supports both multi-channel serial setups and legacy parallel printer interfaces. <\/span><\/li>\n<li><b><span data-font-family=\"default\">Electrical Limits:<\/span><\/b><span data-font-family=\"default\"> Standard D-Sub contacts handle current ratings of <\/span><b><span data-font-family=\"default\">3A to 5A<\/span><\/b><span data-font-family=\"default\"> per pin with contact resistance under <\/span><b><span data-font-family=\"default\">10m\u03a9<\/span><\/b><span data-font-family=\"default\"> and operating temperature ranges from <\/span><b><span data-font-family=\"default\">-55\u00b0C to +105\u00b0C<\/span><\/b><span data-font-family=\"default\">.<\/span><\/li>\n<li><b><span data-font-family=\"default\">Shielding Performance:<\/span><\/b><span data-font-family=\"default\"> Metal and metallized plastic backshells offer <\/span><b><span data-font-family=\"default\">40dB to 60dB<\/span><\/b><span data-font-family=\"default\"> of EMI\/RFI attenuation across frequencies from <\/span><b><span data-font-family=\"default\">30MHz to 1GHz<\/span><\/b><span data-font-family=\"default\">.<\/span><\/li>\n<li><b><span data-font-family=\"default\">Custom Wire Harnesses:<\/span><\/b><span data-font-family=\"default\"> Selecting pre-molded or custom-assembled housings ensures structural stress relief and reliable performance in high-vibration industrial environments.<\/span><\/li>\n<\/ul>\n<h2><b><span data-font-family=\"default\">What is a <a href=\"https:\/\/www.lcsc.com\/search?q=D-Sub&amp;s_z=n_q_D-Sub\">D-Sub Connector<\/a> and How Does It Work?<\/span><\/b><\/h2>\n<p><span data-font-family=\"default\">A <\/span><b><span data-font-family=\"default\">D-Subminiature (D-Sub)<\/span><\/b><span data-font-family=\"default\"> connector is an electrical connector featuring a distinctive D-shaped metal shield that provides structural support, ensures correct orientation, and guards against electromagnetic interference. <\/span><b><span data-font-family=\"default\">D-Sub connectors<\/span><\/b><span data-font-family=\"default\"> consist of two or more rows of contacts enclosed in a protective shell, available in plug (male) and socket (female) configurations. They maintain a critical role in industrial automation, legacy computing, and commercial equipment due to their mechanical durability, low contact resistance, and secure screw-locking mechanisms. <\/span><\/p>\n<h2><b><span data-font-family=\"default\">What Are the Key Differences Between DB9 and DB25 Connectors?<\/span><\/b><\/h2>\n<p><span data-font-family=\"default\">While both options share similar mechanical characteristics, their physical layout, signal capacity, and primary application domains differ significantly. <\/span><\/p>\n<ul>\n<li><b><span data-font-family=\"default\">Physical Dimensions:<\/span><\/b> <b><span data-font-family=\"default\">DB9<\/span><\/b><span data-font-family=\"default\"> shells feature 9 contacts arranged across two rows (5 top, 4 bottom). <\/span><b><span data-font-family=\"default\">DB25<\/span><\/b><span data-font-family=\"default\"> shells house 25 contacts across two rows (13 top, 12 bottom). <\/span><\/li>\n<li><b><span data-font-family=\"default\">Application Scope:<\/span><\/b> <b><span data-font-family=\"default\">DB9<\/span><\/b><span data-font-family=\"default\"> serves primarily as the physical interface for serial protocol buses like RS-232, RS-422, and RS-485. <\/span><b><span data-font-family=\"default\">DB25<\/span><\/b><span data-font-family=\"default\"> supports complex multi-signal configurations, including IEEE 1284 parallel interfaces, multi-channel serial devices, and audio snake systems. <\/span><\/li>\n<li><b><span data-font-family=\"default\">Electrical Parameters:<\/span><\/b><span data-font-family=\"default\"> Standard contacts maintain contact ratings between <\/span><b><span data-font-family=\"default\">3A and 5A<\/span><\/b><span data-font-family=\"default\">, dielectrics withstand <\/span><b><span data-font-family=\"default\">1000V AC RMS<\/span><\/b><span data-font-family=\"default\"> for 1 minute, and insulation resistance exceeds <\/span><b><span data-font-family=\"default\">5000M\u03a9<\/span><\/b><span data-font-family=\"default\"> at <\/span><b><span data-font-family=\"default\">500V DC<\/span><\/b><span data-font-family=\"default\">.<\/span><\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Feature \/ Specification<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><b><span data-font-family=\"default\">DB9 Connector<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><b><span data-font-family=\"default\">DB25 Connector<\/span><\/b><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Pin Count \/ Arrangement<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">9 pins (Rows: 5, 4) <\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">25 pins (Rows: 13, 12) <\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Shell Size Code<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">DE-9 (Standard size E)<\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">DB-25 (Standard size B)<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Primary Interfaces<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">RS-232, CAN bus, RS-485 <\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">Parallel port, IEEE 1284, Audio <\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Current Rating (Per Pin)<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">3A to 5A continuously<\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">3A to 5A continuously<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Maximum Voltage<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">300V AC\/DC RMS<\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">300V AC\/DC RMS<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" width=\"203.86666666666667\"><b><span data-font-family=\"default\">Typical Cable Gauge<\/span><\/b><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"202.2\"><span data-font-family=\"default\">22 AWG to 28 AWG<\/span><\/td>\n<td colspan=\"1\" rowspan=\"1\" width=\"212.2\"><span data-font-family=\"default\">22 AWG to 28 AWG<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b><span data-font-family=\"default\">How to Wire Standard DB9 Pinouts for RS-232 Serial Communication?<\/span><\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-283\" src=\"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg\" alt=\"Standard RS-232 DB9 Pinout Diagram\" width=\"642\" height=\"351\" srcset=\"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg 300w, https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-1024x559.jpg 1024w, https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-768x419.jpg 768w, https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3.jpg 1408w\" sizes=\"auto, (max-width: 642px) 100vw, 642px\" \/><\/p>\n<p><span data-font-family=\"default\">Wiring a <\/span><b><span data-font-family=\"default\">DB9 pinout<\/span><\/b><span data-font-family=\"default\"> for serial interfaces requires mapping line assignments correctly to maintain full-duplex communication and hardware handshaking. <\/span><\/p>\n<ul>\n<li><b><span data-font-family=\"default\">Analyze<\/span><\/b><span data-font-family=\"default\"> the standard RS-232 assignment scheme: Pin 2 (Receive Data \/ RXD), Pin 3 (Transmit Data \/ TXD), and Pin 5 (Signal Ground \/ GND).<\/span><\/li>\n<li><b><span data-font-family=\"default\">Verify<\/span><\/b><span data-font-family=\"default\"> control lines: Pin 1 (Data Carrier Detect \/ DCD), Pin 4 (Data Terminal Ready \/ DTR), Pin 6 (Data Set Ready \/ DSR), Pin 7 (Request to Send \/ RTS), Pin 8 (Clear to Send \/ CTS), and Pin 9 (Ring Indicator \/ RI).<\/span><\/li>\n<li><b><span data-font-family=\"default\">Select<\/span><\/b><span data-font-family=\"default\"> between straight-through or null-modem cabling. Straight-through cables connect matching pin numbers directly for DTE-to-DCE setups. Null-modem configurations swap RXD\/TXD (Pins 2 and 3) and cross-connect RTS\/CTS (Pins 7 and 8) for direct computer-to-computer connections.<\/span><\/li>\n<li><b><span data-font-family=\"default\">Inspect<\/span><\/b><span data-font-family=\"default\"> solder joints or crimp connections to ensure contact resistance remains below <\/span><b><span data-font-family=\"default\">10m\u03a9<\/span><\/b><span data-font-family=\"default\">.<\/span><\/li>\n<\/ul>\n<h2><b><span data-font-family=\"default\">How to Wire DB25 Pinouts for RS-232 and Parallel Interfaces?<\/span><\/b><\/h2>\n<p><span data-font-family=\"default\">The <\/span><b><span data-font-family=\"default\">DB25 pinout<\/span><\/b><span data-font-family=\"default\"> serves dual roles depending on whether you configure it for RS-232 serial or IEEE 1284 parallel operations. <\/span><\/p>\n<ul>\n<li><b><span data-font-family=\"default\">Map<\/span><\/b><span data-font-family=\"default\"> RS-232 serial lines: Pin 2 (TXD), Pin 3 (RXD), Pin 4 (RTS), Pin 5 (CTS), Pin 6 (DSR), Pin 7 (Signal Ground), Pin 8 (DCD), and Pin 20 (DTR).<\/span><\/li>\n<li><b><span data-font-family=\"default\">Configure<\/span><\/b><span data-font-family=\"default\"> IEEE 1284 parallel pinouts: Pin 1 (Strobe), Pins 2-9 (Data Bits 0-7), Pin 10 (Acknowledge), Pin 11 (Busy), Pin 12 (Paper Out), Pin 13 (Select), and Pins 18-25 (Ground Return Paths).<\/span><\/li>\n<li><b><span data-font-family=\"default\">Measure<\/span><\/b><span data-font-family=\"default\"> loop resistance across ground lines to confirm ground loops do not induce noise levels higher than <\/span><b><span data-font-family=\"default\">50mV peak-to-peak<\/span><\/b><span data-font-family=\"default\"> on critical data channels.<\/span><\/li>\n<\/ul>\n<h2><b><span data-font-family=\"default\">How Do You Select the Right Backshell Housing for Your Assembly?<\/span><\/b><\/h2>\n<p><span data-font-family=\"default\">Selecting an appropriate hood or backshell protects fragile wire terminations, maintains strain relief, and prevents stray noise from entering signal lines. <\/span><\/p>\n<ul>\n<li><b><span data-font-family=\"default\">Evaluate<\/span><\/b><span data-font-family=\"default\"> environmental shielding needs. Metal (zinc die-cast) and metallized plastic housings provide <\/span><b><span data-font-family=\"default\">40dB to 60dB<\/span><\/b><span data-font-family=\"default\"> of shield effectiveness across frequencies from <\/span><b><span data-font-family=\"default\">30MHz to 1GHz<\/span><\/b><span data-font-family=\"default\">. Plastic housings suit light-duty, cost-sensitive, non-shielded applications.<\/span><\/li>\n<li><b><span data-font-family=\"default\">Determine<\/span><\/b><span data-font-family=\"default\"> cable exit directions. Choose <\/span><b><span data-font-family=\"default\">180-degree straight<\/span><\/b><span data-font-family=\"default\"> exit hoods for direct inline cabling, <\/span><b><span data-font-family=\"default\">90-degree right-angle<\/span><\/b><span data-font-family=\"default\"> hoods for tight spatial enclosures, or <\/span><b><span data-font-family=\"default\">45-degree angled<\/span><\/b><span data-font-family=\"default\"> entry housings for dense rack arrangements.<\/span><\/li>\n<li><b><span data-font-family=\"default\">Verify<\/span><\/b><span data-font-family=\"default\"> strain relief mechanism compatibility. Ensure internal clamping screws or rubber grommets clamp the outer cable jacket firmly, resisting tensile pull forces up to <\/span><b><span data-font-family=\"default\">150N<\/span><\/b><span data-font-family=\"default\">.<\/span><\/li>\n<\/ul>\n<h2><b><span data-font-family=\"default\">Frequently Asked Questions<\/span><\/b><\/h2>\n<h4><b><span data-font-family=\"default\">1.<\/span><\/b><b><span data-font-family=\"default\">What is the difference between a DB9 connector and an DE-9 connector?<\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">&#8220;DB9&#8221; is the widely used common term, but &#8220;DE-9&#8221; is the technically accurate original designation. The &#8220;D&#8221; stands for the D-Sub series, &#8220;E&#8221; specifies the smallest shell size, and &#8220;9&#8221; denotes the pin count.<\/span><\/p>\n<h4><b><span data-font-family=\"default\">2.<\/span><\/b><b><span data-font-family=\"default\">What is the maximum cable length for RS-232 DB9 communication?<\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">At standard baud rates of 19,200 bps, unshielded RS-232 cable lengths should not exceed <\/span><b><span data-font-family=\"default\">15 meters (50 feet)<\/span><\/b><span data-font-family=\"default\">. Using low-capacitance shielded cables from <\/span><b><span data-font-family=\"default\">LCSC Cable<\/span><\/b><span data-font-family=\"default\"> allows longer cable runs up to <\/span><b><span data-font-family=\"default\">100 meters<\/span><\/b><span data-font-family=\"default\"> at reduced transmission speeds like 4,800 bps.<\/span><\/p>\n<h4><b><span data-font-family=\"default\">3.<\/span><\/b><b><span data-font-family=\"default\">Can I adapt a DB25 port to a DB9 port directly?<\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">Yes, using a passive pin adapter or custom cable assembly. Because both formats use the same underlying RS-232 voltage signaling scheme, signal wires simply map directly between corresponding pins without requiring active protocol converters.<\/span><\/p>\n<h4><b><span data-font-family=\"default\">4.<\/span><\/b><b><span data-font-family=\"default\">How do gold pin plating thicknesses affect connector lifetime?<\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">Gold plating shields copper contacts from oxidation and corrosion. Gold flash (1-3\u00b5in) withstands up to <\/span><b><span data-font-family=\"default\">50 mating cycles<\/span><\/b><span data-font-family=\"default\">, making it ideal for stationary connections. Heavy gold plating (15-30\u00b5in) supports over <\/span><b><span data-font-family=\"default\">500 mating cycles<\/span><\/b><span data-font-family=\"default\"> in high-wear application environments.<\/span><\/p>\n<h4><b><span data-font-family=\"default\">5.<\/span><\/b><b><span data-font-family=\"default\">Why does my D-Sub connection require screw-lock hardware?<\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">Jack screws (typically 4-40 UNC threads) mechanically fasten plug and socket shells together. This prevents accidental disconnections caused by mechanical vibration, cable strain, or accidental pulling in industrial control systems.<\/span><\/p>\n<h2><b><span data-font-family=\"default\">Conclusion: Final Verdict<\/span><\/b><\/h2>\n<p><span data-font-family=\"default\">Building robust, reliable interconnect systems relies on matching the right pin configurations, housings, and shielding techniques to your operational demands. For standard 9-line serial communications, <\/span><b><span data-font-family=\"default\">DB9<\/span><\/b><span data-font-family=\"default\"> provides a compact and economical footprint. For complex parallel or multi-signal wiring, <\/span><b><span data-font-family=\"default\">DB25<\/span><\/b><span data-font-family=\"default\"> delivers the expanded contact capacity necessary for stable performance. Pair your connectors with metallized or die-cast backshells to eliminate signal degradation from EMI. <\/span><\/p>\n<h4><b><span data-font-family=\"default\">Find What You Need on <a href=\"https:\/\/lcsccable.com\/\">LCSC Cable<\/a><\/span><\/b><\/h4>\n<p><span data-font-family=\"default\">We support custom cable development including prototype sampling, covering consumer electronics, industrial systems and specialty applications. You can explore LCSC Cable&#8217;s extensive online catalog to find fully certified cables that match your design requirements, helping you build systems that deliver stable performance for years to come. <\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Key Takeaways Standardized Signals: DB9 connectors primarily support serial communications like RS-232, while DB25 supports both multi-channel serial setups and legacy parallel printer interfaces. Electrical Limits: Standard D-Sub contacts handle current ratings of 3A to 5A per pin with contact resistance under 10m\u03a9 and operating temperature ranges from -55\u00b0C to +105\u00b0C. Shielding Performance: Metal and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"iawp_total_views":49,"footnotes":""},"categories":[1],"tags":[67,78],"class_list":["post-280","post","type-post","status-publish","format-standard","hentry","category-technical-guides","tag-connectors","tag-d-sub"],"blocksy_meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring &amp; Housings<\/title>\n<meta name=\"description\" content=\"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring &amp; Housings\" \/>\n<meta property=\"og:description\" content=\"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog | LCSC Custom Cables\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-04T03:12:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-08T05:48:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1408\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"lcsccable\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"lcsccable\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/\"},\"author\":{\"name\":\"lcsccable\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#\\\/schema\\\/person\\\/e5c1fabf6eaa55b42a9887b2ca410c3c\"},\"headline\":\"D-Sub Connector Guide: DB9, DB25 Pinouts and Housings\",\"datePublished\":\"2026-09-04T03:12:32+00:00\",\"dateModified\":\"2026-09-08T05:48:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/\"},\"wordCount\":1043,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image-3-300x164.jpg\",\"keywords\":[\"Connectors\",\"D-Sub\"],\"articleSection\":[\"Technical Guides\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/\",\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/\",\"name\":\"D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring & Housings\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image-3-300x164.jpg\",\"datePublished\":\"2026-09-04T03:12:32+00:00\",\"dateModified\":\"2026-09-08T05:48:17+00:00\",\"description\":\"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image-3-300x164.jpg\",\"contentUrl\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/image-3-300x164.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/d-sub-connector-guide-db9-db25-pinouts-and-housings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"D-Sub Connector Guide: DB9, DB25 Pinouts and Housings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/\",\"name\":\"Blog | LCSC Custom Cables\",\"description\":\"LCSC Custom Cables Blogs and News\",\"publisher\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#organization\",\"name\":\"Blog | LCSC Custom Cables\",\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Frame-1410083835-1.jpg\",\"contentUrl\":\"https:\\\/\\\/blogs.lcsccable.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Frame-1410083835-1.jpg\",\"width\":360,\"height\":360,\"caption\":\"Blog | LCSC Custom Cables\"},\"image\":{\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/#\\\/schema\\\/person\\\/e5c1fabf6eaa55b42a9887b2ca410c3c\",\"name\":\"lcsccable\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g\",\"caption\":\"lcsccable\"},\"sameAs\":[\"https:\\\/\\\/blogs.lcsccable.com\"],\"url\":\"https:\\\/\\\/blogs.lcsccable.com\\\/blog\\\/author\\\/lcsccable\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring & Housings","description":"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/","og_locale":"en_US","og_type":"article","og_title":"D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring & Housings","og_description":"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.","og_url":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/","og_site_name":"Blog | LCSC Custom Cables","article_published_time":"2026-09-04T03:12:32+00:00","article_modified_time":"2026-09-08T05:48:17+00:00","og_image":[{"width":1408,"height":768,"url":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3.jpg","type":"image\/jpeg"}],"author":"lcsccable","twitter_card":"summary_large_image","twitter_misc":{"Written by":"lcsccable","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#article","isPartOf":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/"},"author":{"name":"lcsccable","@id":"https:\/\/blogs.lcsccable.com\/blog\/#\/schema\/person\/e5c1fabf6eaa55b42a9887b2ca410c3c"},"headline":"D-Sub Connector Guide: DB9, DB25 Pinouts and Housings","datePublished":"2026-09-04T03:12:32+00:00","dateModified":"2026-09-08T05:48:17+00:00","mainEntityOfPage":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/"},"wordCount":1043,"commentCount":0,"publisher":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/#organization"},"image":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#primaryimage"},"thumbnailUrl":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg","keywords":["Connectors","D-Sub"],"articleSection":["Technical Guides"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/","url":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/","name":"D-Sub Connector Guide: DB9 vs DB25 Pinouts, Wiring & Housings","isPartOf":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#primaryimage"},"image":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#primaryimage"},"thumbnailUrl":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg","datePublished":"2026-09-04T03:12:32+00:00","dateModified":"2026-09-08T05:48:17+00:00","description":"Master D-Sub connectors with our guide to DB9 and DB25 pinouts, RS-232 wiring, and housing selection. Build durable custom cable systems.","breadcrumb":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#primaryimage","url":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg","contentUrl":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/09\/image-3-300x164.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/blogs.lcsccable.com\/blog\/d-sub-connector-guide-db9-db25-pinouts-and-housings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blogs.lcsccable.com\/blog\/"},{"@type":"ListItem","position":2,"name":"D-Sub Connector Guide: DB9, DB25 Pinouts and Housings"}]},{"@type":"WebSite","@id":"https:\/\/blogs.lcsccable.com\/blog\/#website","url":"https:\/\/blogs.lcsccable.com\/blog\/","name":"Blog | LCSC Custom Cables","description":"LCSC Custom Cables Blogs and News","publisher":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blogs.lcsccable.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blogs.lcsccable.com\/blog\/#organization","name":"Blog | LCSC Custom Cables","url":"https:\/\/blogs.lcsccable.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blogs.lcsccable.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/01\/Frame-1410083835-1.jpg","contentUrl":"https:\/\/blogs.lcsccable.com\/wp-content\/uploads\/2026\/01\/Frame-1410083835-1.jpg","width":360,"height":360,"caption":"Blog | LCSC Custom Cables"},"image":{"@id":"https:\/\/blogs.lcsccable.com\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/blogs.lcsccable.com\/blog\/#\/schema\/person\/e5c1fabf6eaa55b42a9887b2ca410c3c","name":"lcsccable","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bb749d73bfa55048ada0c400d0a94f579a31e7b3b5303a1c8869325293de532b?s=96&d=mm&r=g","caption":"lcsccable"},"sameAs":["https:\/\/blogs.lcsccable.com"],"url":"https:\/\/blogs.lcsccable.com\/blog\/author\/lcsccable\/"}]}},"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/posts\/280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/comments?post=280"}],"version-history":[{"count":5,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/posts\/280\/revisions"}],"predecessor-version":[{"id":288,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/posts\/280\/revisions\/288"}],"wp:attachment":[{"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/media?parent=280"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/categories?post=280"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.lcsccable.com\/blog\/wp-json\/wp\/v2\/tags?post=280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}